Form No. PDS CK3B.24.2
Cased Horizontal
Furnace Coil
CK3B
Sizes A024 thru A060
This horizontal N-Coil is designed to provide the highest
standard of reliability and durability. The CK3B coil casing is
unpainted embossed galvanized steel. The cabinet is fully
insulated to minimize energy loss.
The CK3B is designed for application with horizontal furnaces.
The 2-directional airflow allows for either horizontal-right or
horizontal-left furnace fit-up. This coil is ideally suited for either
attic or crawl space installation.
Our advanced manufacturing methods give a better bond of the
fin and tube. Contaminants are not introduced into coil during
manufacturing. Galvanic action is minimized. The coils are
approved for air conditioning or heat pump application in the
horizontal configuration.
The CK3B coil includes a refrigerant control metering device for
improved serviceability over check valves and expansion
devices used in conventional coils. Sweat-type connections are
furnished for installation of the refrigerant tubes.
The coil is designed to provide improved condensate removal.
The robust condensate pan has brass inserts in the primary and
secondary drain connections and meets FHA requirements.
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Furnace Coil

Form No. PDS CK3B.24.2 Cased HorizontalFurnace Coil CK3B Sizes A024 thru A060 This horizontal N-Coil is designed to provide the higheststandard of re

Strona 2

—2— MODEL NUMBER NOMENCLATURE CK3 C—CoilK—Cased, N-Coil3—Horizontal5—Upflow/DownflowCERTIFICATION APPLIES ONLY WHENUSED WITH PROPER COMPONENTSAS LIST

Strona 3 - DIMENSIONS (In.)

—3— A97521 DIMENSIONS (In.) UNITABCDESHIPPINGWEIGHTIn. In. In. In. In. Lb CK3BXA024 17-9/16 19-1/16 10-1/16 5/8 16 36.0CK3BXA030 17-9/16 19-1/16 10-1

Strona 4 - COOLING CAPACITIES (MBH)

—4— COOLING CAPACITIES (MBH) See notes on page 5. UNITSIZEINDOOR COILAIRSATURATED TEMPERATURE LEAVING EVAPORATOR ( ° F)30 35 40 45 50CFM EWB TC SHC B

Strona 5 - 81 82 83 84 84 Over 85

—5— CFM — Cubic Ft per Minute EWB — Entering Wet Bulb ( ° F) LWB — Leaving Wet Bulb ( ° F) TC — Total Cooling Capacity 1000 Btuh SHC — Total Sensible

Strona 6 - Horizontal Right

—6— TYPICAL N-COIL HORIZONTAL INSTALLATIONSHorizontal LeftFILLER PLATEN-COILAIRFLOWFURNACEDRAINCONNECTIONA97203FILLER PLATEN-COILAIRFLOWFURNACEDRAIN

Strona 7

—7—

Strona 8 - SERVICE TRAINING

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: PDS CK3B.24.1B© 1997 Bryant

Komentarze do niniejszej Instrukcji

Brak uwag