SPECIFICATIONS Continued
* The ampacity of non-metallic (NM) sheathed cable shall be that of 60°C (140°F) conductors per NEC 1999, Article 336-26. If wire used is other than
specified in chart, refer to applicable tables available in 1999 NEC. Copper wire must be used from disconnect to unit.
Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2%.
‡ Units may use fuses or circuit breakers (U.S. only).
‡‡ Consult low-ambient control Installation Instructions for application.
*** Isolation relay required.
††† Fan motor with ball bearings required.
UNIT SIZE-SERIES 042-C 048-C 060-C
ELECTRICAL
Unit Volts—Phase—Hertz 208/230—1—60 208/230—1—60 208/230—3—60 208/230—1—60 208/230—3—60
Operating Voltage Range 187—253
Unit Ampacity for Wire Sizing (MCA) 30.1 31.0 19.5 32.7 23.0
Min Wire Size (60°C/75°C Copper) (AWG)* 8/8 8/8 14/14 8/8 12/12
Maximum Length (60°C/75°C) (Ft)† 100/95 39/37 94/90 55/52
Max Branch Circuit Fuse Size (Amps)‡ 50 50 30 50 35
Compressor Rated Load Amps 23.2 23.9 14.7 25.0 17.3
Locked Rotor Amps 104.0 137.0 91.0 150.0 123.0
Fan Motor HP and RPM 1/5 & 825 1/4 & 1100
Full Load Amps 1.1 1.4
COMPRESSOR AND REFRIGERANT
Compressor Manufacturer Scroll
Refrigerant Charge (Lb) 10.38 11.13 18.19
Refrigerant Tubes (In. OD)
Vapor and Liquid (Up to 80 Ft)
7/8
3/8
1-1/8
OUTDOOR COIL AND FAN
Coil Face Area (Sq Ft) 16.03 18.50 24.66
Rated Airflow (CFM) 2800 3400
OPTIONAL EQUIPMENT
Time-Delay Relay KAATD0101TDR
Outdoor Thermostat KHAOT0301FST
Secondary Outdoor Thermostat KHAOT0201SEC
Cycle Protector KSACY0101AAA
Crankcase Heater KAACH1201AAA Standard
Compressor Start Assist—
Capacitor/Relay KSAHS1501AAA
KSAHS1701AAA N/A KSAHS1601AAA N/A
Sound Hood KSASH0601COP KSASH2101COP
TXV Kits (Hard Shutoff) KSATX0601HSO KSATX0701HSO KSATX1001HSO
Low-Pressure Switch Standard
High-Pressure Switch KHAHI0101HPS
Low-Ambient Pressure Switch*** KSALA0201R22
MotorMaster®—Low-Ambient
Controller††† KSALA0401AAA
Ball Bearing Fan Motor HC38GE231
HC40GE232
Liquid Line Filter Drier (RCD) KH43LE062
Evaporator Freeze Thermostat‡‡ KAAFT0101AAA
Isolation Relay‡‡ KHAIR0101AAA
Liquid Solenoid Valve KHALS0401LLS
Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
2-Stage Heat, 1-Stage Cool TSTATPPBHP01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATPPSHP01
Outdoor Sensor (For Programmable
Thermostat) TSTATXXSEN01-B
Backplate for Non-Programmable
Thermostat
TSTATXXBBP01
Backplate for Programmable Thermostat
TSTATXXPBP01