Physical Dimensions
INSTALLATION
Overall Cabinet Discharge Connection
Water Connections Electrical Knockouts
Return Connection
using std deluxe filter rack (±0.10 in)
Model
ABCDEFGHJKLMN
PQ R
STUVWY Z
Width Depth Height
Supply
Depth
Supply
Width
Water
Out
Water
In
Cond-
ensate
HWG
Power
Supply
Ext
Pump
Low
Voltage
Return
Width
Return
Height
036 inches 25 25 51 1/2 13 15/16 13 15/16 1 5 1/2 5 14 2 7/8 8 7/8 2 1/2 5 1/2 1 3/4 6 22 5/8 12 1/8 9 5/8 8 2 1 7/8 21 3/4 21 3/4
mm 635 635 1308 354 354 25 140 127 356 73 225 64 140 44 152 575 308 244 203 51 48 552 552
042 inches 28 1/8 28 1/8 59 1/2 17 15/16 17 15/16 2 5/8 5 5 1/8 17 5/8 2 7/8 8 7/8 2 1/8 5 3/4 1 1/2 6 1/4 22 5/8 12 1/8 9 5/8 8 2 1 7/8 24 5/8 29 3/8
mm 714 714 1511 456 456 67 127 130 448 73 225 54 146 38 159 575 308 244 203 51 48 626 746
048 inches 28 1/8 28 1/8 59 1/2 17 15/16 17 15/16 2 5/8 5 5 1/8 17 5/8 2 7/8 8 7/8 2 1/8 5 3/4 1 1/2 6 1/4 22 5/8 12 1/8 9 5/8 8 2 1 7/8 24 5/8 29 3/8
mm 714 714 1511 456 456 67 127 130 448 73 225 54 146 38 159 575 308 244 203 51 48 626 746
060 inches 28 1/8 28 1/8 63 3/8 17 15/16 17 15/16 2 5/8 5 5 1/8 17 5/8 2 7/8 8 7/8 2 1/8 5 3/4 1 1/2 6 1/4 22 5/8 12 1/8 9 5/8 8 2 1 7/8 24 5/8 33 3/8
mm 714 714 1610 456 456 67 127 130 448 73 225 54 146 38 159 575 308 244 203 51 48 626 848
072 inches 28 1/8 28 1/8 63 3/8 17 15/16 17 15/16 2 5/8 5 5 1/8 17 5/8 2 7/8 8 7/8 2 1/8 5 3/4 1 1/2 6 1/4 22 5/8 12 1/8 9 5/8 8 2 1 7/8 24 5/8 33 3/8
mm 714 714 1610 456 456 67 127 130 448 73 225 54 146 38 159 575 308 244 203 51 48 626 848
Vertical unit shipped with deluxe duct collar/filter rack extending from unit 2.75" and is suitable for duct connection.
Rev.: 11/20/01 b
Discharge flange is field installed
duct flange installed (±0.10 in)
Hot Water GeneratorWater and Condensate
1 Water Inlet for Circuit A - 1" FPT Swivel Connection
2 Water Inlet for Circuit B - 1" FPT Swivel Connection
3 Water Outlet for Circuit A - 1" FPT Swivel Connection
4 Water Outlet for Circuit B - 1" FPT Swivel Connection
5 Condensate - 3/4" FPT Connection
6 Hot Water Generator Inlet for Circuit A - 1/2" FPT
7 Hot Water Generator Outlet for Circuit A - 1/2" FPT
8 Low voltage thermostat knockout for 1/2" conduit
9 External Pump Power lmockout for 1/2" conduit
10 Unit power knockout for 3/4" conduit
Legend
CAP Control Access Panel
BSP Blower Service panel
CSP Compressor Service panel
WCP Water Circuit Access Panel
Abbreviations